B-63943EN-1/02 10.AUXILIARY FUNCTION
- 1179 -
When the second auxiliary function with a decimal point is
specified, alarm PS0007 is issued.
When the second auxiliary function is specified with a negative
value, alarm PS0006 is issued.
2. When a command with a decimal point or a negative command is
enabled
(When parameter AUP (No.3450#0) is set to 1)
When the desktop calculator decimal point setting is not
specified (when parameter DPI (No.3401#0) is set to 0), if the
second auxiliary function with no decimal point is specified, the
specified value is output on the code signals as is.
Example:
Specified value Output value
B10 10
When desktop calculator decimal point input is specified (when
parameter DPI (No.3401#0) is set to 1), if the second auxiliary
function with no decimal point is specified, the specified value
multiplied by a magnification is output on the code signals.
(Magnifications are shown in Table 10.1 (a).)
Example:
Specified value Output value
B10 10000 (When metric input is used and
the reference axis is IS-B. The
magnification is 1000.)
When the second auxiliary function with a decimal point is
specified, the specified value multiplied by a magnification is
output to the code signals. (Magnifications are shown in Table
10.1 (a).)
Example:
Specified value Output value
B10. 10000 (When metric input is used and
the reference axis is IS-B. The
magnification is 1000.)
B0.123 1230 (When inch input is used, the
reference axis is IS-B, and
parameter AUX is set to 1. The
magnification is 10000.)
The magnification is determined as shown below according to
the setting unit of the reference axis (specified by parameter
No.1031) and parameter AUX (No.3405#0).