B-63943EN-1/02 1.AXIS CONTROL
- 287 -
#7 #6 #5 #4 #3 #2 #1 #0
6201 SKPXE CSE IGX
[Input type] Parameter input
[Data type] Bit path
# 4 IGX When the high-speed skip function is used, SKIP, SKIPP, and SKIP2
to SKIP8 are:
0: Enabled as skip signals.
1: Disabled as skip signals.
# 5 CSE For the continuous high-speed skip command, high-speed skip signals
are:
0: Effective at either a rising or falling edge (depending on the
setting of bit 6 (SRE) of parameter No. 6200).
1: Effective at both the rising and falling edges.
# 7 SKPXE For the skip function (G31), the skip signal SKIP is:
0: Disabled.
1: Enabled.
Whether the skip signals are enabled or disabled
Parameter
IGX
(No.6201#4)
GSK
(No.6200#0)
SKPXE
(No.6201#7)
Skip signal
SKIPP
Skip signal
SKIP
Multistage skip
signals
SKIP2-SKIP8
0 0 0 Disabled Enabled Enabled
0 1 0 Enabled Enabled Enabled
0 0 1 Disabled Disabled Enabled
0 1 1 Enabled Disabled Enabled
1 0 0 Disabled Disabled Disabled
1 1 0 Disabled Disabled Disabled
1 0 1 Disabled Disabled Disabled
Setting
1 1 1 Disabled Disabled Disabled
Bit 4 (IGX) of parameter No. 6201 is valid for the skip function using
high-speed skip signals (when bit 4 (HSS) of parameter No. 6200 is
set to 1) or for the multistage skip function using high-speed skip
signals (when bit 5 (SLS) of parameter No. 6200 is set to 1).
To use multistage skip signals, the multistage skip function option is
required.
#7 #6 #5 #4 #3 #2 #1 #0
6208 9S8 9S7 9S6 9S5 9S4 9S3 9S2 9S1
[Input type] Parameter input
[Data type] Bit path
9S1 to 9S8 Specify which high-speed skip signal is enabled for the continuous
high-speed skip command G31P90 or the EGB skip command G31.8.
The settings of each bit have the following meaning: