B-63530EN/03 4.DESCRIPTION OF PARAMETERS
- 143 -
1820 Command multiplier for each axis (CMR)
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Data type] Byte axis
Set a command multiplier indicating the ratio of the least command
increment to the detection unit for each axis.
Least command increment = detection unit × command multiplier
Relationship between the increment system and the least command
increment
(1) T series
Least input increment
Least
command
increment
0.001 mm (diameter programming) 0.0005 mm Metric
input
0.001 mm (radius programming) 0.001 mm
0.0001 inch (diameter programming) 0.0005 mm
Metric
machine
Inch input
0.0001 inch (radius programming) 0.001 mm
0.001 mm (diameter programming) 0.00005 inch Metric
input
0.001 mm (radius programming) 0.0001 inch
0.0001 inch (diameter programming) 0.00005 inch
Inch
machine
Inch input
0.0001 inch (radius programming) 0.0001 inch
IS-B
Rotary axis 0.001 deg 0.001 deg
0.0001 mm (diameter programming) 0.00005 mm Metric
input
0.0001 mm (radius programming) 0.0001 mm
0.00001 inch (diameter programming) 0.00005 mm
Metric
machine
Inch input
0.00001 inch (radius programming) 0.0001 mm
0.0001 mm (diameter programming) 0.000005 inchMetric
input
0.0001 mm (radius programming) 0.00001 inch
0.00001 inch (diameter programming) 0.000005 inch
Inch
machine
Inch input
0.00001 inch (radius programming) 0.00001 inch
IS-B
Rotary axis 0.0001 deg 0.0001 deg
(2) M series
Least input increment and least command incrementInput
increment
IS-A IS-B IS-C Units
Metric machine 0.01 0.001 0.0001 mm
Inch machine 0.001 0.0001 0.00001 inch
Rotary axis 0.01 0.001 0.0001 deg