B-63530EN/03 4.DESCRIPTION OF PARAMETERS
- 637 -
4.82 PARAMETERS OF MANUAL HANDLE FEED
#7 #6 #5 #4 #3 #2 #1 #0
12330 GR7 GR6 GR5 GR4 GR3 GR2 GR1 GR0
#7 #6 #5 #4 #3 #2 #1 #0
12331 GRF GRE GRD GRC GRB GRA GR9 GR8
[Data type] Bit
GR0 When PMC group 0 (channel 1) is a Power Mate or I/O Link β, the
pulses from the manual pulse generator connected to the I/O Link are:
0 : Transferred to that group.
1 : Not transferred to that group.
GR1 to GRD When PMC group 1 (channel 1) is a Power Mate or I/O Link β, the
pulses from the manual pulse generator connected to the I/O Link are:
0 : Transferred to that group.
1 : Not transferred to that group.
GRE When PMC group 14 (channel 1) is a Power Mate or I/O Link β, the
pulses from the manual pulse generator connected to the I/O Link are:
0 : Transferred to that group.
1 : Not transferred to that group.
GRF When PMC group 15 (channel 1) is a Power Mate or I/O Link β, the
pulses from the manual pulse generator connected to the I/O Link are:
0 : Transferred to that group.
1 : Not transferred to that group.
NOTE
Set this parameter to 1 when the Power Mate is
connected to the I/O Link.
#7 #6 #5 #4 #3 #2 #1 #0
12332 G27 G26 G25 G24 G23 G22 G21 G20
#7 #6 #5 #4 #3 #2 #1 #0
12333 G2F G2E G2D G2C G2B G2A G29 G28
[Data type] Bit
G20 When PMC group 0 (channel 2) is a Power Mate or I/O Link β, the
pulses from the manual pulse generator connected to the I/O Link are:
0 : Transferred to that group.
1 : Not transferred to that group.
G21 to G2D When PMC group 1 (channel 2) is a Power Mate or I/O Link β, the
pulses from the manual pulse generator connected to the I/O Link are:
0 : Transferred to that group.
1 : Not transferred to that group.
G2E When PMC group 14 (channel 2) is a Power Mate or I/O Link β, the
pulses from the manual pulse generator connected to the I/O Link are:
0 : Transferred to that group.
1 : Not transferred to that group.