4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 436 -
4.43 PARAMETERS OF AUTOMATIC TOOL OFFSET (T
SERIES) AND AUTOMATIC TOOL LENGTH
MEASUREMENT (M SERIES)
#7 #6 #5 #4 #3 #2 #1 #0
6240 AE0
[Data type] Bit
AE0 Measurement position arrival is assumed when the automatic tool
offset signals XAE and ZAE <X004#0 and #1> (T series) or the
automatic tool length measurement signals XAE, YAE, and ZAE
<X004#0, #1, and #2> (M series) are:
0 : 1
1 : 0
Feedrate during measurement of automatic tool offset
6241
Feedrate during measurement of automatic tool length measurement
[Data type] Word
[Unit of data, valid data range]
Valid data range
Input increment Units of data
IS-A, IS-B IS-C
Metric machine 1 mm/min 6 to 15000 6 to 12000
Inch machine 0.1 inch/min 6 to 6000 6 to 4800
This parameter sets the feedrate during measurement of automatic tool
offset (T series) and automatic tool length measurement (M series).