B-63530EN/03 4.DESCRIPTION OF PARAMETERS
- 423 -
6136
Distance D1 to the first stage of positioning by optimal acceleration for each
axis
6137
Distance D2 to the second stage of positioning by optimal acceleration for
each axis
6138
Distance D3 to the third stage of positioning by optimal acceleration for each
axis
[Data type] 2-word axis
[Unit of data]
Input increment IS-A IS-B IS-C Unit
Metric input 0.01 0.001 0.0001 mm
Inch input 0.001 0.0001 0.00001 inch
Rotary axis 0.01 0.001 0.0001 deg
[Valid data range] 0 to 99999999
These parameters set the distances to the first to third stages of
positioning by optimal acceleration for each axis.
Set the positioning distances used when the function for 4-stage
switching of the rapid traverse rate, time constant, and loop gain based
on positioning distance is used.
NOTE
About parameter No. 6136 to No. 6138
1 When these parameters are set, D1 < D2 < D3
must be satisfied.
2 Up to four stages of switching are possible. When
using up to the third stage, for example, set
D3=99999999.
3 Use a diameter value to set an axis for diameter
programming. When 10.000 mm is set in a
parameter above for an axis for diameter
programming, switching is performed on a
boundary where a diameter value of 10.000 mm
has been moved.
4 If both of these parameters (4-stage switching for
each axis) and parameter No. 6141 and No. 6156
(7-stage switching applicable to all axes) are set,
the former parameters have priority.