4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 550 -
SVF In synchronous/composite control, for an axis under synchronous or
composite control on the other path, the feed-forward function and the
cutting feed and rapid traverse switching function are:
0 : Disabled.
1 : Enabled.
NOTE
With the M series, synchronous control only is
enabled.
CPM When composite control is exercised, machine coordinate system
selection (G53) is:
0 : Disabled.
1 : Enabled. (A travel distance is calculated so that a movement is
made according to the machine coordinate system selection of
the composite control target path.)
NA0 When superimposed control is turned off during movement on an axis:
0 : P/S alarm 000 is issued.
1 : P/S alarm 000 is not issued.
NOTE
If this parameter is set to 1, bit 7 (BFA) of
parameter No. 1300 is invalid while superimposed
control is exercised.
SMT When Cs contour control axes are placed under composite control,
torque limit skip for the composite axes of other paths is:
0 : Disabled.
1 : Enabled.
NOTE
When this parameter is set to 1, bit 1 (CZM) of
parameter No. 8161 also needs to be set to 1.
#7 #6 #5 #4 #3 #2 #1 #0
2OV OVL MIX SYN
8166
NOTE
When at least one of these parameters is set, the
power must be turned off before operation is
continued.
[Data type] Bit
SYN For synchronous control:
0 : The 3-path interface is used.
1 : The 2-path interface is used. (Synchronous control involving
axes of path 3 cannot be exercised.)