B-63530EN/03 4.DESCRIPTION OF PARAMETERS
- 531 -
CDI In axis control by the PMC, when diameter programming is specified
for a PMC-controlled axis:
0 : The amount of travel and feedrate are each specified with a
radius.
1 : The amount of travel is specified with a diameter while the
feedrate is specified with a radius.
NOTE
1 This parameter is valid when bit 3 (DIA) of
parameter No.1006 is set to 1.
2 When CDI is set to 1, bit 7 (NDI) of parameter
No.8004 is disabled.
R10 When bit 0 (RPD) of parameter No.8002 is set to 1, the unit for
specifying a rapid traverse rate for the PMC axis is:
0 : 1 mm/min.
1 : 10 mm/min.
DRR For cutting feed per rotation in axis control by PMC, the dry run
function is:
0 : Disabled.
1 : Enabled.
PVP With a speed command in axis control by PMC, position control is:
0 : Not exercised.
1 : Exercised.
NOTE
When using flexible synchronous control or
learning control, set this parameter to 1.
IFV Override for each group in axis control by PMC is:
0 : Disabled.
1 : Enabled.
IGE When a servo alarm about the basic axis occurs, the PMC axis control
alarm signal (EIALx):
0 : Changes to 1.
1 : Remains at 0.
MFD Output by each auxiliary function of the PMC axis control function is:
0 : Disabled.
1 : Enabled.
#7 #6 #5 #4 #3 #2 #1 #0
8006 EAL EZR ESI IPA EML
[Data type] Bit
EML When bit 0 (MLE) of parameter No. 8001 is set to 1, for PMC axes:
0 : The all axis machine lock signal and axis-by-axis machine lock
signals are disabled.
1 : The all axis machine lock signal is disabled and the axis-by-axis
machine lock signals are enabled.