4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 444 -
Override value for clamping the rapid traverse rate used with the manual
handle retrace function
6405
[Data type] Byte
[Unit of data] %
[Valid data range] 0 to 100
This parameter sets an override value for clamping the rapid traverse
rate used with the manual handle retrace function. If a value greater
than 100 is set in this parameter, the rapid traverse rate is clamped to
an override of 100%. This parameter is invalid if 0 is set in this
parameter. In this case, the setting of bit 0 (HRP) of parameter No.
6400 is used.
Travel distance per pulse generated from the manual pulse generator for the
manual handle retrace function
6410
[Data type] Byte
[Unit of data] %
[Valid data range] 0 to 100
This parameter sets the travel distance per pulse generated from the
manual pulse generator for the manual handle retrace function.
The distance traveled by the machine when the manual handle is
actually turned can be found by the following expression:
Setting of this
parameter
8
Specified
speed
×
Number of
handle pulses
per second
×
Handle
magnification
×
100
×
1000