4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 544 -
CRZ When the composite control function for zero point return commands
for Cs contour axes is used (bit 1 (CZM) of parameter No.8161 = 1),
for a positioning command for a CS contour axis immediately after
composite control switching between Cs contour axes:
0 : Normal positioning operation is performed.
1 : Positioning operation including zero point return is performed.
NSR When an axis under synchronous control is placed in the servo-off
state:
0 : Synchronous control is canceled.
1 : Synchronous control is not canceled if a setting is made to
disable follow-up for the axis (if bit 0 (FUP) of parameter No.
1819 is set to 1).
#7 #6 #5 #4 #3 #2 #1 #0
MUMx MCDx MPSx MPMx OMRx PKUx SERx SMRx
8162
[Data type] Bit axis
SMRx Mirror-image synchronous control is:
0 : Not applied. (The master and slave axes move in the same
direction.)
1 : Applied. (The master and slave axes move in opposite
directions.)
SERx The synchronous error is:
0 : Not detected.
1 : Detected.
NOTE
When both master and slave axes move in
synchronous control, the positioning deviations of
the corresponding axes are compared with each
other. If the difference is greater than or equal to
the value specified in parameter No.8181, an alarm
occurs. When either axis is in the parking or
machine-locked state, however, the synchronous
error is not detected.
PKUx In the parking state,
0 : The absolute, relative, and machine coordinates are not updated.
1 : The absolute and relative coordinates are updated. The machine
coordinates are not updated.
OMRx Mirror-image superimposed control is:
0 : Not applied. (The superimposed pulse is simply added.)
1 : Applied. (The inverted superimposed pulse is added.)