4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 226 -
#7 #6 #5 #4 #3 #2 #1 #0
3207 OM4
NOTE
When at least one of these parameters is set, the
power must be turned off before operation is
continued.
[Data type] Bit
OM4 A message displayed on the external operator message screen can
have:
0 : Up to 256 characters, and just a single message can be displayed.
1 : Up to 64 characters, and up to four messages can be displayed.
#7 #6 #5 #4 #3 #2 #1 #0
3208 COK SKY
[Data type] Bit
SKY The function key
SYSTEM
on the MDI panel is:
0 : Enabled.
1 : Disabled.
COK The automatic screen erase function is:
0 : Enabled.
1 : Disabled.
NOTE
1 The setting specified for path 1 is followed. The
setting for path 2/3 or loader is ignored.
2 If this parameter is set to 1, manual screen erasure
by the CAN + FUNCTION key is enabled,
irrespective of the setting of parameter No. 3123.
#7 #6 #5 #4 #3 #2 #1 #0
3209 UPP NFU MPD
[Data type] Bit
MPD When a subprogram is executed, the main program number is:
0 : Not displayed.
1 : Displayed. (for 10.4” LCD and 9.5” LCD)
NFU If a function key is pressed to clear or display the screen display with
the erase CRT screen display function/automatic Erase CRT screen
display function, screen switching based on the function key is:
0 : Performed.
1 : Not performed.
UPP A program protected using cnc_upload3() of the
FOCAS1/ETHERNET function is:
0 : Not uploaded.
1 : Uploaded if searchable.