B-63530EN/03 4.DESCRIPTION OF PARAMETERS
- 533 -
#7 #6 #5 #4 #3 #2 #1 #0
8008 MIRx
[Data type] Bit axis
MIRx When a PMC axis control command is issued in mirror image mode,
the mirror image is:
0 : Not considered.
1 : Considered.
This parameter is valid when PMC signals MI1 to MI8 <G106#0 to
#7> are set to 1 or bit 0 (MIRx) of parameter No. 0012 is set to 1.
8010 Selection of the DI/DO group for each axis controlled by the PMC
[Data type] Byte axis
[Valid data range] 1 to 4
Specify the DI/DO group to be used to specify a command for each
PMC-controlled axis.
Value Description
1 DI/DO group A (G142 to G153) is used.
2 DI/DO group B (G154 to G165) is used.
3 DI/DO group C (G166 to G177) is used.
4 DI/DO group D (G178 to G189) is used.
8020 Low-speed feedrate at reference position return in axis control by PMC (FL)
[Data type] Word axis
[Unit of data, valid data range]
Valid data range
Input increment Units of data
IS-B IS-C
Metric machine 1 mm/min 6 to 15000 6 to 12000
Inch machine 0.1 inch/min 6 to 6000 6 to 4800
Rotary axis 1 deg/min 6 to 15000 6 to 12000
This parameter sets the low-speed feedrate (FL) at a reference position
return on axis control by PMC.
NOTE
If 0 is specified, the value of parameter No. 1425 is
used.