4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 42 -
4.12 PARAMETERS OF AXIS CONTROL/INCREMENT SYSTEM
#7 #6 #5 #4 #3 #2 #1 #0
1001 INM
NOTE
When at least one of these parameters is set, the
power must be turned off before operation is
continued.
[Data type] Bit
INM Least command increment on the linear axis
0 : In mm (metric system machine)
1 : In inches (inch system machine)
#7 #6 #5 #4 #3 #2 #1 #0
IDG XIK SFD DLZ JAX
1002
IDG XIK AZR SFD DLZ JAX
[Data type] Bit
JAX Number of axes controlled simultaneously in jog feed, manual rapid
traverse and manual reference position return
0 : 1 axis
1 : 3 axes
DLZ Function setting the reference position without dog
0 : Disabled
1 : Enabled (enabled for all axes)
NOTE
1 This function can be specified for each axis by bit 1
(DLZx) of parameter No.1005.
2 For a system including an axis of Cs contour
control or spindle positioning, avoid using this
parameter. Use bit 1 (DLZx) of parameter No. 1005
instead to set just a required axis.
SFD The function for shifting the reference position is
0 : Not used.
1 : Used.