4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 682 -
NOTE
2 Safety speed parameters No. 1942, and No. 13821
through No. 13824 are safety parameters, so that
these parameters are protected using the key and
code of Dual Check Safety. To modify a safety
speed parameter, set a code for safety parameters
as the key for safety parameters (parameter No.
3226).
3 When the value of safety speed parameters (No.
1942, No. 13821 through No. 13824) has been
changed, the power must be turned off before
operation is continued.
4 When diameter programming is used, set a speed
based on diameter programming.
1943 Safe machine position of each axis (+ direction)
1944 Safe machine position of each axis (- direction)
13831 Safe machine position 1 of each axis (+ direction)
13832 Safe machine position 1 of each axis (- direction)
13833 Safe machine position 2 of each axis (+ direction)
13834 Safe machine position 2 of each axis (- direction)
13835 Safe machine position 3 of each axis (+ direction)
13836 Safe machine position 3 of each axis (- direction)
13837 Safe machine position 4 of each axis (+ direction)
13838 Safe machine position 4 of each axis (- direction)
[Data type] 2-word axis
[Unit of data, valid data range]
Increment system IS-A IS-B IS-C Unit
Metric machine 0.01 0.001 0.0001 mm
Inch machine 0.001 0.0001 0.00001 inch
Set a safe machine position for each axis.
The CNC and monitor always check the machine position on each
linear axis in the dual check safety.
In safety signal mode B (state in which a guard open request is input,
and the guard is closed), if there is at least one linear axis whose
machine position is not in the safe machine position, the guard unlock
signal (*LGD) is set to 0 to disable guard unlocking. The state in
which the machine positions of all linear axes are within the safe
machine positions is one condition for setting the guard unlock signal
(*LGD) to 1 (to enable guard unlocking). If the machine position on a
linear axis exceeds the safe machine position in safety signal mode C
(state in which a guard open request is input and the guard is open), a
servo alarm No.477 or No.495 is issued.