B-63530EN/03 4.DESCRIPTION OF PARAMETERS
- 203 -
#7 #6 #5 #4 #3 #2 #1 #0
OPC AHC OFA
3110
OPC AHC
[Data type] Bit
OFA The axis names on the offset screen, Y-axis offset screen, and 4th axis
offset screen are:
0 : Always X, Z, Y, and E.
1 : As specified by parameter No. 1020.
AHC With a soft key, the alarm history:
0 : Can be cleared.
1 : Cannot be cleared.
OPC On the operation history screen, the [CLEAR] soft key is:
0 : Not enabled.
1 : Enabled.
#7 #6 #5 #4 #3 #2 #1 #0
3111 NPA OPS OPM SVP SPS SVS
[Data type] Bit
SVS Servo tuning screen
0 : Not displayed
1 : Displayed
SPS Spindle tuning screen
0 : Not displayed
1 : Displayed
SVP Synchronization errors displayed on the spindle tuning screen
0 : Instantaneous values are displayed.
1 : Peak-hold values are displayed.
OPM Operating monitor
0 : Not displayed
1 : Displayed
OPS The speedometer on the operating monitor screen indicates:
0 : Spindle motor speed
1 : Spindle speed
NPA Action taken when an alarm is generated or when an operator message
is entered
0 : The display shifts to the alarm or message screen.
1 : The display does not shift to the alarm or message screen.