B-63530EN/03 4.DESCRIPTION OF PARAMETERS
- 327 -
5014 Maximum value of incremental input for tool wear compensation
[Data type] 2-word
[Unit of data]
Input increment IS-A IS-B IS-C Unit
Metric input 0.01 0.001 0.0001 mm
Inch input 0.001 0.0001 0.00001 inch
[Valid data range]
Input increment IS-A IS-B IS-C
Metric input 0 to 99999 0 to 999999 0 to 9999999
Inch input 0 to 99999 0 to 999999 0 to 9999999
Set the maximum allowable value for the tool wear compensation
value, input as an incremental value. If the incremental input value
(absolute value) exceeds the set value, the following alarm or warning
message is output:
Input from MDI
Warning: Setting value out of range.
Input using G10
P/S alarm No.032: Offset value is out of range by G10.