4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 80 -
#7 #6 #5 #4 #3 #2 #1 #0
RTV MIF
1403
NOTE
When at least one of these parameters is set, the
power must be turned off before operation is
continued.
[Data type] Bit
MIF Cutting feedrates at feed per minute is specified by F commands
0 : In units of 1 mm/min for millimeter machines or 0.01 inches/min
for inch machines.
1 : In unit of 0.001 mm/min for millimeter machines or 0.00001
inches/min for inch machines.
NOTE
M series are not equipped with this parameter.
Cutting feedrates are specified by F commands in
units of 0.001 mm/min for millimeter machines or
0.00001 inches/min for inch machines.
RTV Override while the tool is retracting in threading
0 : Override is effective.
1 : Override is not effective.
#7 #6 #5 #4 #3 #2 #1 #0
1404 FC0 HCF FRV F8A DLF HFC
[Data type] Bit
HFC The feedrate for helical interpolation is:
0 : Clamped so that the feedrates along a circular and linear axis do
not exceed the maximum cutting feedrate specified by parameter
(No.1422 or 1430).
1 : Clamped so that the composite feedrate along a circular and
linear axis does not exceed the maximum cutting feedrate
specified by parameter (No.1422).
DLF After a reference position is set, manual reference position return
performed at:
0 : Rapid traverse rate (parameter No.1420)
1 : Manual rapid traverse rate (parameter No.1424)
NOTE
This parameter selects a feedrate for reference
position return performed without dogs. This
parameter also selects a feedrate when manual
reference position return is performed according to
bit 7 (SJZ) of parameter No.0002 using rapid
traverse without deceleration dogs after a
reference position is set.