4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 648 -
4.84 PARAMETERS OF ACCELERATIOON CONTROL
12700
Speed at overtravel occurrence time during linear acceleration/deceleration
before interpolation (for stored stroke check 2)
12701
Speed at overtravel occurrence time during linear acceleration/deceleration
before interpolation (for stored stroke check 3)
[Data type] Word
[Unit of data, valid data range]
Valid data range
Increment system Units of data
IS-B IS-C
Metric machine 1 mm/min 6 to 15000 6 to 12000
Inch machine 0.1 inch/min 6 to 6000 6 to 4800
Rotary axis 1 deg/min 6 to 15000 6 to 12000
If a setting is made to issue an overtravel alarm during linear
acceleration/deceleration before interpolation, deceleration is
performed beforehand to set the speed specified in this parameter
when the alarm is issued (when the limit is reached). By using this
parameter, an overrun distance traveled when an overtravel alarm is
issued can be reduced.
When bit 2 (DS2) of parameter No. 1604 is set to 1, set a speed at
overtravel alarm issue time for stored stroke check 2 in parameter No.
12700.
When bit 3 (DS3) of parameter No. 1604 is set to 1, set a speed at
overtravel alarm issue time for stored stroke check 3 in parameter No.
12701.
NOTE
If 0 is set in parameter No. 12700 or No. 12701
when bit 2 (DS2) or bit 3 (DS3) of parameter No.
1604 is set to 1, the setting of parameter No. 1784
is used.