4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 46 -
HJZx When a reference position is already set:
0 : Manual reference position return is performed with deceleration
dogs.
1 : Manual reference position return is performed using rapid
traverse without deceleration dogs, or manual reference position
return is performed with deceleration dogs, depending on the
setting of bit 7 (SJZ) of parameter No.0002.
NOTE
When the function for setting the reference position
without dogs (refer to bit 1 (DLZ) of parameter No.
1002) is used, positioning at the reference position
is performed at the rapid traverse rate at all times
in reference position return operation after
reference position establishment, regardless of the
setting of HJZ.
EDPx External deceleration signal in the positive direction for each axis
0 : Valid only for rapid traverse
1 : Valid for rapid traverse and cutting feed
EDMx External deceleration signal in the negative direction for each axis
0 : Valid only for rapid traverse
1 : Valid for rapid traverse and cutting feed
MCCx When an axis become the removal state using the controlled axis
removal signal or setting:
0 : MCC is turned off
1 : MCC is not turned off. (Servo motor excitation is turned off, but
the MCC signal of the servo amplifier is not turned off.)
NOTE
This parameter is used to remove only one axis, for
example, when a two-axis or three-axis amplifier is
used. When two-a axis or three-axis amplifier is
used and only one axis is removed, servo alarm
No.401 (V-READY OFF) is usually issued.
However, this parameter, when set to 1, prevents
servo alarm No.401 from being issued.
Note, however, that disconnecting a servo amplifier
from the CNC will cause the servo amplifier to
enter the V-READY OFF status. This is a
characteristic of all multiaxis amplifiers.
RMBx Releasing the assignment of the control axis for each axis (signal input
and setting input)
0 : Invalid
1 : Valid