4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 308 -
#7 #6 #5 #4 #3 #2 #1 #0
STT
4901
[Data type] Bit
STT In multi-path or multi-spindle control, the spindle that detects spindle
speed fluctuation is:
0 : The first spindle of the path for which spindle speed fluctuation
detection is specified.
1 : The spindle selected by the position coder feedback signal.
NOTE
When this parameter is set to 0, it is necessary that
the first spindle should be selected by the position
coder feedback signal.
4911
Rapid (q) of the fluctuation of spindle speed which is assumed to be the
specified spindle speed
[Data type] Word
[Unit of data, valid data range]
Unit of data
1% 0. 1% (T series)
Valid data range
1 to 100 1 to 1000
NOTE
Unit of data depends on bit 0 (FLR) of parameter
No.4900 (T series only)
Set the ratio (q) of the spindle speed which is assumed to be the
specified spindle speed in the spindle speed fluctuation detection
function.
Let the commanded speed be Sc. When the actual spindle speed
reaches between (Sc-Sq) and (Sc+Sq), it is assumed to be the
commanded speed.
The spindle speed fluctuation detection starts.
where,
q
Sq = Sc ×
100