4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 488 -
4.54 PARAMETERS OF REFERENCE POSITION SETTING
WITH MECHANICAL STOPPER
7181
First withdrawal distance in reference position setting with mechanical
stopper
[Data type] 2-word axis
[Unit of data]
Input increment IS-A IS-B IS-C Unit
Metric input 0.01 0.001 0.0001 mm
Inch input 0.001 0.0001 0.00001 inch
[Valid data range] -99999999 to 99999999
When the reference position setting with mechanical stopper is used,
this parameter sets a distance an axis, along which withdrawal is
performed after the mechanical stopper is hit (distance from the
mechanical stopper to the withdrawal point).
NOTE
Set the same direction as that set in bit 5 (ZMIx) of
parameter No. 1006. Cycle operation cannot be
started if the opposite direction is set.
7182
Second withdrawal distance in reference position setting with mechanical
stopper
[Data type] 2-word axis
[Unit of data]
Input increment IS-A IS-B IS-C Unit
Metric input 0.01 0.001 0.0001 mm
Inch input 0.001 0.0001 0.00001 inch
[Valid data range] -99999999 to 99999999
When the reference position setting with mechanical stopper is used,
this parameter sets a distance an axis, along which withdrawal is
performed after the mechanical stopper is hit (distance from the
mechanical stopper to the withdrawal point).
NOTE
Set the same direction as that set in bit 5 (ZMIx) of
parameter No. 1006. Cycle operation cannot be
started if the opposite direction is set.