4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 658 -
Name of the first spindle for load meter display (first character)
13140
Name of the first spindle for load meter display (second character)
13141
Name of the second spindle for load meter display (first character)
13142
Name of the second spindle for load meter display (second character)
13143
Name of the third spindle for load meter display (first character)
13144
Name of the third spindle for load meter display (second character)
13145
[Data type] Byte
Set the name of each spindle used for spindle load meter display by
specifying character codes. As a name to be displayed on the screen,
an arbitrary character string (not longer than two characters)
consisting of numerical characters, alphabetic characters, katakana
characters, and symbols (other than "!") can be used.
NOTE
1 These parameters can be used only for current
position display on the left side of the display
screen in a one-path system and for load meter
display on the program check screen in a two-path
or three-path system when a 9.5/10.4-inch display
unit (with 12-soft key type) is used.
2 For the character codes, see the character code
correspondence table in Appendix A.
3 Character code 33 ("!") cannot be displayed.
4 If 0 is set as a character code, the following are
displayed:
First spindle: S1
Second spindle: S2
Third spindle: S3