4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 288 -
3772 Maximum spindle speed
[Data type] 2-word
[Unit of data] min
-1
[Valid data range] 0 to 32767
This parameter sets the maximum spindle speed.
When a command specifying a speed exceeding the maximum speed
of the spindle is specified, or the speed of the spindle exceeds the
maximum speed because of the spindle speed override function, the
spindle speed is clamped at the maximum speed set in the parameter.
NOTE
1 For M series, this parameter is valid if the function
of constant surface speed control is provided or bit
4 (GTT) of parameter No. 3706 is set to 1.
2 When the constant surface speed control option is
selected, the spindle speed is clamped at the
maximum speed, regardless of whether the G96
mode or G97 mode is specified.
3 When 0 is set in this parameter, the speed of the
spindle is not clamped.
4 When spindle speed command control is applied
using the PMC, this parameter has no effect, and
the spindle speed is not clamped.
5 When the multi-spindle control option is selected,
set the maximum speed for each spindle in the
following parameters:
Parameter No.3772:
Sets the maximum speed for the first spindle.
Parameter No.3802:
Sets the maximum speed for the second spindle.
Parameter No.3822:
Sets the maximum speed for the third spindle.
Parameter No.3850:
Sets the maximum speed for the fourth spindle.
(for Series 16i/160i/160is only)