B-63530EN/03 4.DESCRIPTION OF PARAMETERS
- 163 -
STP When the dual check safety function is used, an MCC off Test at
power-off time is:
0 : Conducted. (When the power is turned on, the warning "Conduct
Safety Test." is indicated, and the MCC off Test execution
request signal RQT is output.)
1 : Not conducted.
NOTE
1 The STP parameter is used temporarily, for
example, when a MCC off Test is not to be made at
power-on as in the case of machine adjustment.
Usually, set STP = 0.
2 Even when STP = 1, a MCC off Test is required if
the power is turned 24 hours or more after the
completion of the previous MCC off Test.
WARNING
Set STP = 0 after the STP parameter is used
temporarily as in the case of machine adjustment.
DCE The dual check safety function is:
0 : Disabled.
1 : Enabled.
NOTE
Usually set the DCE = 1 in the dual check safety
function. The system cannot start-up because
MCC-on enable signal (MCF) = 0 when the DCE =
0.
#7 #6 #5 #4 #3 #2 #1 #0
1903 FO2 FO1
NOTE
When at least one of these parameters is set, the
power must be turned off before operation is
continued.
[Data type] Bit
FO1 The first FSSB I/O unit is:
0 : Not used.
1 : Used.