B-63530EN/03 4.DESCRIPTION OF PARAMETERS
- 9 -
4.1 PARAMETERS OF SETTING
#7 #6 #5 #4 #3 #2 #1 #0
0000 SEQ INI ISO TVC
At least one of these parameters can also be set on the “Setting
screen”.
[Data type] Bit
TVC TV check
0 : Not performed
1 : Performed
ISO Code used for data output
0 : EIA code
1 : ISO code
INI Unit of input
0 : In mm
1 : In inches
SEQ Automatic insertion of sequence numbers
0 : Not performed
1 : Performed
When a program is prepared by using MDI keys in the part program
storage and edit mode, a sequence number can automatically be
assigned to each block in set increments. Set the increment to
parameter No. 3216.
#7 #6 #5 #4 #3 #2 #1 #0
0001 FCV
At least one of these parameters can also be set on the “Setting
screen”.
[Data type] Bit
FCV Tape format
0 : Series 16 standard format
1 : Series 15 format
NOTE
1 Programs created in the Series 15 tape format can
be used for operation on the following functions:
(1) Subprogram call M98
(2) Threading with equal leads G32 (T series)
(3) Canned cycle G90, G92, G94 (T series)
(4) Multiple repetitive canned cycle G71 to G76 (T
series)
(5) Drilling canned cycle G73, G74, G76, G80 to
G89 (M series)
(6) Cutter compensation C (M series)
2 When the tape format used in the Series 15 is used
for this CNC, some limits may add. Refer to the
Series 16i/18i/160i/180i/160is/180is-MODEL B
OPERATOR'S MANUAL.