4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 498 -
#7 #6 #5 #4 #3 #2 #1 #0
7505 HUNx HSCx
NOTE
When at least one of these parameters is set, the
power must be turned off before operation is
continued.
[Data type] Bit axis
HSCx Specifies whether each axis is used for high-speed distribution in a
high-speed cycle or with a high-speed remote buffer.
0 : Not used for high-speed distribution.
1 : Used for high-speed distribution
HUNx Specifies whether the unit of data to be distributed during high-speed
cycle machining (G05) is ten times the least input increment.
0 : The unit of data is the same as the least input increment.
1 : The unit of data is ten times the least input increment.
NOTE
This parameter is used when a data item to be
distributed exceeds a word in terms of the least
input increment or the maximum travel speed.
The data to be distributed for machining in a
high-speed cycle for the axes in which this
parameter HUNX = 1 is set.
Thus, when using parameter HUNx, set one-tenth
the data to be distributed for machining in a
high-speed cycle for the set axis.