4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 442 -
4.46 PARAMETERS OF MANUAL HANDLE RETRACE
#7 #6 #5 #4 #3 #2 #1 #0
MG4 MGO RVN HMP HM8 HM5 HFW HRP
6400
[Data type] Bit
HRP With the manual handle retrace function, the rapid traverse rate is
clamped, assuming that:
0 : An override of 10% is used.
1 : An override of 100% is used.
(See the description of parameter No. 6405 as well.)
HFW With the manual handle retrace function, program execution can be
performed:
0 : In both forward and backward directions.
1 : Only in the forward direction.
HM8, HM5
HM8 HM5 M code group setting
0 0 Standard (20 groups of four)
0 1 16 groups of five
1 0 10 groups of eight
These parameters set the number of M code groups and the number of
M codes in each group.
(See explanations of parameters Nos. 6411 to 6490.)
When 16 groups of five are used, the meanings of parameters are
changed as follows:
Group A No.6411(1) to No.6415(5)
Group B No.6416(1) to No.6420(5)
:
Group P No.6486(1) to No.6490(5)
When 10 groups of eight are used, they are changed as follows:
Group A No.6411(1) to No.6418(8)
Group B No.6419(1) to No.6426(8)
:
Group J No.6483(1) to No.6490(8)
HMP When reverse or backward movement is disabled for a path:
0 : Reverse or backward movement is not disabled for other paths.
1 : Reverse or backward movement is also disabled for other paths.