4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 190 -
#7 #6 #5 #4 #3 #2 #1 #0
3006 EPS EPN GDC
[Data type] Bit
GDC As the deceleration signal for reference position return:
0 : X009/X007 is used.
1 : G196/G1196 is used. (X009/X007 is disabled.)
EPN Workpiece number search signals are assigned to:
0 : PN1, PN2, PN4, PN8, and PN16 <G009>.
1 : EPN0 to EPN13 <G024, G025>.
EPS When a program is searched using the workpiece number search
function, it is started by:
0 : Automatic operation start signal ST (when automatic operation
(memory operation) is started).
1 : Workpiece number search start signal EPNS <G025#7>. (Search
is not started by ST.)
#7 #6 #5 #4 #3 #2 #1 #0
3008 XSG
NOTE
When at least one of these parameters is set, the
power must be turned off before operation is
continued.
[Data type] Bit
XSG The signal assigned to an X address is:
0 : Assigned to a fixed address.
1 : Changeable to an arbitrary address. (However, the emergency
stop signal *ESP<X008#4> cannot be changed.)
When this bit is set to 1, set parameter No. 3012 to No. 3014.