B-63530EN/03 4.DESCRIPTION OF PARAMETERS
- 523 -
7741 Retracted distance for each axis
[Data type] 2-word axis
Unit of data
Input increment
IS-B IS-C
Metric input 0.001 mm 0.0001 mm
Inch input 0.0001 inch 0.00001 inch
[Valid range] -99999999 to 99999999
This parameter sets the retracted distance for each axis.
7745
Time constant for linear acceleration/deceleration in retract operation for
each axis
[Data type] Word axis
[Unit of data] msec
[Valid range] 0 to 4000
This parameter sets an acceleration rate for linear
acceleration/deceleration in retract operation based on the
general-purpose retract function. Set a time (time constant) used to
reach the feedrate set in parameter No. 7740 for each axis.
NOTE
This parameter is valid when bit 0 (ACR) of
parameter No. 7704 is set to 1.
7750
Feedrate during retraction performed when an alarm is issued
[Data type] 2-word axis
[Unit of data, valid data range]
Valid data range
Input increment Units of data
IS-B IS-C
Metric machine 1 mm/min 30 to 240000 6 to 100000
Inch machine 0.1 inch/min 30 to 96000 6 to 48000
This parameter sets the feedrate during retraction performed when an
alarm is issued. Whether to perform the retraction depends on the
setting of bit 3 (ART) of parameter No. 7702.