4.SERVO FUNCTION DETAILS B-65270EN/05
- 114 -
4.2 HIGH-SPEED HRV CURRENT CONTROL
4.2.1 Servo HRV3 Control
(1) Series and editions of applicable servo software
(Series 30i,31i,32i)
Series 90D0/A(01) and subsequent editions
Series 90E0/A(01) and subsequent editions
(Series 15i-B,16i-B,18i-B,21i-B,0i-B, Power Mate i)
Series 90B0/A(01) and subsequent editions
Series 90B1/A(01) and subsequent editions
Series 90B6/A(01) and subsequent editions
(Series 0i-C,0i Mate-C,20i-B)
Series 90B5/A(01) and subsequent editions
(2) Setting parameters for servo HRV3 control
<1> See Subsection 4.1.1, and make settings for servo HRV2 control.
<2> Set servo HRV3 current control. (For each axis)
#7 #6 #5 #4 #3 #2 #1 #0
1707(FS15i)
HRV3
2013(FS30i,16i)
HRV3(#0) 1: Uses servo HRV3 control.
0: Does not use servo HRV3 control.
NOTE
1 When servo HRV3 control is used with Series
90E0, a multiple of 4 cannot be set in parameter
No. 1023. Skip multiples of 4 when setting the
parameter.
Example: when using eight axes with Series 90E0,
set parameter No. 1023 as follows:
1,2,3,5,6,7,9,10
<3> Set the cutting/rapid velocity loop gain switching function.
#7 #6 #5 #4 #3 #2 #1 #0
1742(FS15i)
VGCCR
2202(FS30i,16i)
VGCCR (#1) 1: Uses the cutting/rapid velocity loop gain switching function.
0: Does not use the cutting/rapid velocity loop gain switching
function.