2. SETTING αiS/αiF/βiS SERIES SERVO PARAMETERS B-65270EN/05
- 8 -
2.1 INITIALIZING SERVO PARAMETERS
2.1.1 Before Servo Parameter Initialization
Before starting servo parameter initialization, confirm the following:
<1> NC model (ex.: Series 16i-B)
<2> Servo motor model (ex.: α
iF8/3000)
<3> Pulsecoder built in a motor (ex.:
αiA1000)
<4> Is the separate position detector used? (ex.: Not used)
<5> Distance the machine tool moves per revolution of the motor
(ex.:10 mm per one revolution)
<6> Machine detection unit (ex.:0.001 mm)
<7> NC command unit (ex.:0.001 mm)