B-65270EN/05 4.SERVO FUNCTION DETAILS
- 161 -
4.5.7 Dual Position Feedback Function
Optional function
(1) Overview
A machine with large backlash may cause vibrations in a closed loop
system even if it works steadily in a semi–closed loop system. The
dual position feedback function controls the machine so that it
operates as steadily as in the semi–close system.
This function is optional function
.
(2) Control method
The following block diagram shows the general method of dual
position feedback control:
Velocity
control
MCMD
Σ
Velocity feedback
Kp
Amplifier
Conversion
coefficient
Σ
Primary delay
time constant
Position feedback (from motor)
Position feedback (from separate detector)
ER1 Motor
Position gain
+
−
+
+
+
−
Separate
detector
ER
ER2
+
−
+
−
Fig. 4.5.7 Block diagram of dual position feedback control
As shown in Fig. 4.5.7, error counter ER1 in the semi-closed loop
system and error counter ER2 in the closed loop system are used. The
primary delay time constant is calculated as follows:
Primary delay time constant = (1 + τs)
−1
The actual error, ER, depends on the time constant, as described
below:
(1) When time constant τ is 0 ⋅⋅⋅⋅⋅⋅ (1 + τs)
−1
= 1
ER = ER1 + (ER2 − ER1) = ER2 (error counter of the full-closed
loop system)
(2) When time constant τ is ∞ ⋅⋅⋅⋅⋅⋅ (1 + τs)
−1
= 0
ER = ER1 (error counter of the semi-closed loop system)
This shows that control can be changed according to the primary delay
time constant. The semi-closed loop system applies control at the
transitional stage and the full-closed loop system applies control in
positioning.
This method allows vibrations during traveling to be controlled as in
the semi-closed loop system.