2. SETTING αiS/αiF/βiS SERIES SERVO PARAMETERS B-65270EN/05
- 18 -
Example of setting
If the gear reduction ratio between the rotation axis motor and table is
10:1 and the detection unit is 1/1000 degrees
The table rotates through 360/10 degrees when the motor makes one
turn.
The number of position pulses necessary for the motor to make one
turn is:
360/10 ÷ (1/1000) = 36000 pulses
F
FG numerato
36,000 36
= =
F⋅FG denominator 1,000,000 1,000
If the gear reduction ratio between the rotation axis motor and table is
300:1 and the detection unit is 1/10000 degrees
The table rotates through 360/300 degrees when the motor makes one
turn.
The number of position pulses necessary for the motor to make one
turn is:
360/300 ÷ (1/1000) = 12000 pulses
F
FG numerator 12,000 12
= =
F
⋅
FG denominator 1,000,000 1000
(b) Full-closed feedback loop
Setting for use of a separate detector (full-closed)
Number of position pulses corresponding
F⋅FG numerator (≤ 32767) to a predetermined amount of travel
= (as irreducible fraction)
F⋅FG denominator (≤ 32767) Number of position pulses corresponding
to a predetermined amount of travel from
a separate detector
Example of setting
To detect a distance of 1-µm using a 0.5-µm scale, set the following:
(L represents a constant distance.)
umerator of F
⋅
FG L/1 1
= =
Denominator of F
⋅
FG L/0.5 2
Other FFG (numerator/denominator) setting examples
Scale resolution
Detection unit
1 µm 0.5 µm 0.1 µm 0.05 µm
1µm 1 / 1 1 / 2 1 / 10 1 / 20
0.5µm - 1 / 1 1 / 5 1 / 10
0.1µm - - 1 / 1 1 / 2