4.SERVO FUNCTION DETAILS B-65270EN/05
- 238 -
4.9 SERIAL FEEDBACK DUMMY FUNCTIONS
4.9.1 Serial Feedback Dummy Functions
(1) Overview
The serial feedback dummy functions ignore servo alarms of
non-servo axes.
(2) Series and editions of applicable servo software
(Series 30i,31i,32i)
Series 90D0/A(01) and subsequent editions
Series 90E0/A(01) and subsequent editions
(Series 15
i-B,16i-B,18i-B,21i-B,0i-B,0i Mate-B,Power Mate i)
Series 90B0/A(01) and subsequent editions
Series 90B1/A(01) and subsequent editions
Series 90B6/A(01) and subsequent editions
(Series 0
i-C,0i Mate-C,20i-B)
Series 90B5/A(01) and subsequent editions
Series 9096 does not support the settings of such dummy axes.
(This series is not planed to support this function in the future. If
necessary, use a series supporting this function.)
(3) Setting the built-in Pulsecoder-based feedback dummy function
Setting the function bit shown below enables ignoring of alarms
related to the servo amplifier and built-in Pulsecoder for an axis not
connected to a servo control circuit.
#7 #6 #5 #4 #3 #2 #1 #0
1953 (FS15i)
SERD
2009 (FS30i, 16i)
SERD (#0) Specifies whether to enable the serial feedback dummy function as
follows:
1: To enable
0: To disable
1788 (FS15i)
Set 0.
2165 (FS30i, 16i)
To use the serial feedback dummy functions, a non-zero value must be
entered as the motor number.
1874 (FS15i)
Motor number
2020 (FS30i, 16i)
Enter an appropriate non-zero value.
Example) 15