Descri
tion
Design.
Date Ed
2005.07.15
SHEET
DRAW. No.
CUST.
TITLE
Ma
Newly designed
Notice of the Update of Digital Servo
Software for Series 16i etc. (90B1/03)
B-65270EN/05-001
FANUC LTD
9/19
01
Attached 3. Changes of Standard Parameter Table
The standard parameters for new model βiS(HV) series have been added.
HRV1 HRV2,3
Motor Model Motor ID No. Motor ID No.
βiS2/4000HV
151 251
βiS4/4000HV
164 264
βiS8/3000HV
167 267
βiS12/3000HV
170 270
βiS22/2000HV
178 278
*Please refer to Table 1 about the standard parameters.
To improve stability during motor deceleration, following model’s parameters are changed.
Motor Model Motor ID No.
αiF4/4000HV
175
αiS12/4000HV
189
αiF12/3000HV
195
*Please refer to Table 2 about the standard parameters.
The function bit which can detect overheat alarm of linear motor is set valid in the standard
parameter table.
The following motors’ parameter No2300#7 is changed to 1 for the detection the oveheat alarm via PMC.
Motor model (Motor ID No)For HRV1 Control:
Motor Model Motor ID No. Reference Motor Model Motor ID No. Reference
LiS1500B1/4
90
LiS15000C2/3
123
LiS3000B2/2
91
LiS300A1/4
124
LiS6000B2/2
92
LiS600A1/4
125
LiS9000B2/2
93
LiS900A1/4
126
LiS15000C2/2
94
LiS6000B2/4
127 160A
Drive
LiS3000B2/4
120
LiS9000B2/2
128 160A
Drive
LiS6000B2/4
121
LiS9000B2/4
129 360A
Drive
LiS9000B2/4
122
LiS15000C2/2
130 360A
Drive
*Please refer to Table 3 about the standard parameters.
Standard parameters for linear motor (LiS series) HRV2,3 control have been added.
Motor Model Motor ID No. Reference Motor Model Motor ID No. Reference
LiS300A1/4
351
LiS1500B1/4
358
LiS600A1/4
353
LiS3000B2/2
361
LiS900A1/4
355
200VDrive
LiS4500B2/2HV
363
400VDrive