4.SERVO FUNCTION DETAILS B-65270EN/05
- 128 -
(b) Feed-forward, TCMD filter, 1/2 PI current control switching
[Series and editions of applicable servo software]
(Series 30i,31i,32i)
Series 90D0/A(01) and subsequent editions
Series 90E0/A(01) and subsequent editions
(Series 15i-B,16i-B,18i-B,21i-B,0i-B,0i Mate-B, Power Mate i)
Series 90B0/A(01) and subsequent editions
Series 90B1/A(01) and subsequent editions
Series 90B6/A(01) and subsequent editions
(Series 0i-C,0i Mate-C,20i-B)
Series 90B5/A(01) and subsequent editions
<1> Cutting/rapid feed-forward switching function
The position feed-forward coefficient and the velocity
feed-forward coefficient can also be changed without using fine
acc./dec. To do this, use the cutting/rapid feed-forward switching
function.
#7 #6 #5 #4 #3 #2 #1 #0
2602 (FS15i)
FFCHG
2214 (FS30i,16i)
1: Enables the cutting/rapid feed-forward switching function.
0: Disables the cutting/rapid feed-forward switching function.
[Series30i, 16i, and so on]
Cutting/rapid feed-forward switching function Position FF Velocity FF
No. 2214#4=0 (disabled) Always
Rapid traverse
No. 2092 No. 2069
No. 2214#4=1 (enabled)
Cutting feed
No. 2144 No. 2145
[Series15i]
Cutting/rapid feed-forward switching function Position FF Velocity FF
No. 2602#4=0 (disabled) Always
Rapid traverse
No. 1985 No. 1962
No. 2602#4=1 (enabled)
Cutting feed
No. 1767 No. 1768
<2> TCMD filter switching
When high frequency vibration occurs only in rapid traverse, use
of the TCMD filter, rather than the resonance elimination filter,
is sometimes effective. On the other hand, in cutting feed,
inserting an unnecessary TCMD filter lowers the vibration limit
of the velocity loop gain because of the delay in the filter. In
such a case, using the TCMD filter only for rapid traverse is