B-65270EN/05 APPENDIX I.SERVO CHECK BOARD OPERATING PROCEDURE
- 527 -
(a) Connection between a servo check board and a personal
computer (IBM PC/AT compatible)
Connect servo check board connector CNA1 to the printer port of
a personal computer. The printer port must support bidirectional
communication mode. (Measurement is impossible in ECP
mode.)
Windows
does not support the servo adjustment software (SD).
Use it in full-screen mode or MS-DOS mode.
(b) Basic operating instructions
<1> Enter "SD INIT" at a DOS prompt. The software starts with
all its states initialized, and its main screen appears (if the
name of the software's executable file is "SD.EXE").
The main screen lets you measure and view data.
Entering "CTRL + letter" switches the drawing mode.
Select a drawing mode suitable for the data to be observed.
(Pressing the ? key displays a list of the available drawing
modes.)
Drawing mode examples:
CTRL + X: XY mode (XY display)
CTRL + T: XTYT mode (time axis display)
Main screen
Parameter setting System setting
F5
F10
F9
F10
F1: Measure data
F2: Change the number of measurement points
F3: Change the display range
F7: Save data
F4: Edit comments
F8: Read data
F10: End
Fig. I (e) Servo adjustment software basic configuration and key manipulation