D.PARAMETERS RELATED TO HIGH-SPEED AND HIGH-PRECISION OPERATIONS APPENDIX B-65270EN/05
- 468 -
(6) Parameters for Series 30i and 31i (parameters needed to use HRV4)
• Parameters that do not usually need tuning so often and can be left at fixed
values
Parameter No.
FS30i
Standard setting value Description
2004
0X000011
(Note 1)
HRV3 current control (in a mode other than high-speed HRV
control)
2014#0 1
In the G05.4Q1 command, high-speed HRV control (HRV4
current control)
2300#0 1 Extended HRV function
2202#1 1 Cutting/rapid velocity loop gain switching function
2040 Standard parameter for HRV2 Current integral gain
2041 Standard parameter for HRV2 Current proportional gain
2334 150
Current loop gain magnification for high-speed HRV current
control
NOTE
1 Keep the bit indicated with X (bit 6) at the standard
setting.
• Parameters that need tuning
Parameter No.
FS30i and so on
Setting Description Items to be referenced in tuning
2107 150
Cutting load inertia ratio override
(in % units)
While checking vibration at stop, abnormal
sound during low-speed movement, vibration
during high-speed rotation, and so on, find the
vibration limit, and set about 70% of the limit.
2335 200
Cutting load inertia ratio override
(in % units) when high-speed HRV
current control is in use
While checking vibration at stop, abnormal
sound during low-speed movement, vibration
during high-speed rotation, and so on, find the
vibration limit, and set about 70% of the limit.