4.SERVO FUNCTION DETAILS B-65270EN/05
- 152 -
(3) Set the disturbance elimination filter gain to 500, and check the
frequency characteristics with SERVO GUIDE while increasing
the gain for inverse model starting with 100 in steps of 100.
Adjust the value so that the amplitude of the gain swell part
becomes small.
Measurement example using SERVO GUIDE (after adjustment)
(4) Note that the velocity loop gain of higher frequencies is
increased and even a violent vibration may be caused simply by
enabling the disturbance elimination filter function. If a vibration
occurs, increase the inverse function gain gradually, and check
the vibration of the torque command. If the vibration becomes
greater, decrease the inverse function gain. If the vibration can
not be reduced by increasing and decreasing the inverse function
gain, change the filter time constant by ±50 to eliminate the
vibration.
(5) If the frequency of vibration is higher than 100 Hz, use a separate
machine resonance prevention function such as the vibration
suppression filter and torque command filter.
Improved