C.FUNCTION-SPECIFIC SERVO PARAMETERS APPENDIX B-65270EN/05
- 442 -
: Parameters set up automatically or cleared at initialization
Parenthesized parameters : Common parameters that are also used for other functions
Parameter number
FS15i FS30i,16i,etc.
Meaning
2786
2787
2373
2374
Lifting function against gravity at emergency stop : distance to lift
Lifting function against gravity at emergency stop : lifting time
→ 4.11.3
1745#4
1745#5
2205#4
2205#5
Separate detector hardware disconnection stop distance reduction
function
For axes under synchronization control, this bit is also set.
→ 4.11.4
2600#7 2212#7 OVL and OVC alarm stop distance reduction function → 4.11.5
[Unexpected disturbance torque detection functions] (Optional functions)
1958#0 2016#0 Unexpected disturbance torque detection function
1740#5 2200#5 Improvement in the accuracy of an estimated disturbance load
2716 2302
Improvement in the accuracy of an estimated disturbance load (A
Q-phase current phase lag is compensated for.)
1980 2087 Torque offset
1727 2116 Dynamic friction compensation value
2758 2345 Dynamic friction compensation value in the stop state
2759 2346 Dynamic friction compensation limit value
1997 2104 Unexpected disturbance torque detection alarm level
1996 2103 Retrace distance
1740#3 2200#3
Cutting/traverse unexpected disturbance torque detection switching
function
2603#7 2215#7
Cutting/traverse unexpected disturbance torque detection switching
function type-2
(1997) (2104) Unexpected disturbance torque detection alarm level for cutting
1765 2142
Unexpected disturbance torque detection alarm level for rapid
traverse
2684#2 2271#2
2-axes simultaneous retract function at unexpected disturbance
torque detection
2603#1 2215#1 Torque offset canceling when an emergency stop is released
→ 4.12
[Linear motor functions]
1954#2 2010#2 Linear motor control function
1705 2112 AMR conversion coefficient 1
1761 2138 AMR conversion coefficient 2
1762 2139 AMR offset
2683#0 2270#0 AMR offset setting range expansion from -60 degrees to +60 degrees
(2628) (2185) Position pulse conversion coefficient
1740#6 2200#6 The velocity loop proportional gain format is changed.
1750#2 2210#2 Current gain internally 4 times function
1753
1754
1755
2130
2131
2132
Smoothing compensation performed twice per pole pair
Smoothing compensation performed four times per pole pair
Smoothing compensation performed six times per pole pair
2782
2783
2784
2369
2370
2371
Smoothing compensation performed twice per pole pair (negative
direction)
Smoothing compensation performed four times per pole pair
(negative direction)
Smoothing compensation performed six times per pole pair (negative
direction)
→ 4.14
1743#6 2203#6 Linear motor quadruple smoothing compensation
2713#7 2300#7 1: Determines overheat via PMC.
[Torque control functions]
1951#7 2007#7 Torque control type 1
→ 4.15