2. SETTING αiS/αiF/βiS SERIES SERVO PARAMETERS B-65270EN/05
- 30 -
(c) Parameter setting for the serial output type rotary encoder
* For explanations about the rotary encoders RCN220, RCN223,
RCN723, and RCN727 made by Heidenhain, see "Parameter
setting for the rotary encoders RCN220, RCN223, RCN723, and
RCN727 made by Heidenhain."
(Parameter setting method)
In addition to the conventional settings for a separate detector (bit 1 of
parameter No. 1815 (Series15
i, 30i, 16i, 18i, 21i, 20i, 0i, and Power
Mate
i), bit 3 of parameter No. 1807 (Series 15i), and if needed,
FSSB), note the following parameters:
[Flexible feed gear]
Parameters Nos. 1977 and 1978 (Series 15i) or Nos. 2084 and 2085
(Series 30
i, 16i and so on)
Flexible feed gear (N/M) =
(Amount of table movement [deg] per detector revolution) /
(detection unit [deg]) / 1,000,000
[Number of position pulses]
Parameter No. 1891 (Series 15
i) or No. 2024 (Series 30i, 16i and so
on)
Number of position pulses = 12500×(motor-to-table deceleration ratio)
* If the result of the above calculation does not fall in the setting
range (0 to 32767) for the number of position pulses, use
“position feedback pulse conversion coefficient” to specify the
number of position pulses according to the following procedure.
Number of position pulses to be set = A × B
Select B so that A is within 32767. Then, set the following:
A: Position pulses parameter (32767 or less)
No.1891 (Series15
i), No.2024 (Series 30i, 16i and so on)
B: Position pulses conversion coefficient parameter
No.2628 (Series15
i), No.2185 (Series 30i, 16i and so on)
(Example of parameter setting)
[System configuration]
• The Series 16i is used.
• The least input increment of the controller is 1/1000 degree.
• The amount of movement per motor revolution is 180 degrees
(deceleration ratio: 1/2)
• Table-to-separate-encoder reduction ratio = 1/1