B-65270EN/05 4.SERVO FUNCTION DETAILS
- 227 -
4.8.2 Low-speed Integral Function
(1) Overview
To ensure that the motor responds quickly, a small time constant must
be set so that a command enabling quick startup is issued.
If the time constant is too small, vibration or hunting occurs because
of the delayed response of the velocity loop integrator, preventing
further reduction of the time constant.
With the low-speed integral function, velocity loop integrator
calculation is performed in low-speed mode only. This function
ensures quick response and high stability while maintaining the
positioning characteristics in the low-speed and stop states.
(2) Series and edition of applicable servo software
(Series 30i,31i,32i)
Series 90D0/A(01) and subsequent editions
Series 90E0/A(01) and subsequent editions
(Series 15i-B,16i-B,18i-B,21i-B,0i-B,0i Mate-B,Power Mate i)
Series 9096/A(01) and subsequent editions
Series 90B0/A(01) and subsequent editions
Series 90B1/A(01) and subsequent editions
Series 90B6/A(01) and subsequent editions
(Series 0i-C,0i Mate-C,20i-B)
Series 90B5/A(01) and subsequent editions
(3) Setting parameters
<1> Specify whether to enable the low-speed integral function.
#7 #6 #5 #4 #3 #2 #1 #0
1957 (FS15i)
SSG1
2015 (FS30i, 16i)
SSG1 The low-speed integral function is used.
1: Valid
0: Invalid
<2> Specify whether to enable integration at acc./dec. time.
1714 (FS15i)
Limit speed for disabling low-speed integral at acceleration
2029 (FS30i, 16i)
The integral gain is invalidated during acceleration at a speed higher
than or equal to the specified speed.
[Unit of data] Rotational motor: 0.01 min
-1
Linear motor: 0.01 mm/min
[Valid data range] 0 to 32767
[Recommended value] 1000