B-65270EN/05 2. SETTING αiS/αiF/βiS SERIES SERVO PARAMETERS
- 43 -
(2) Series and editions of applicable servo software
(Series 16i-B,18i-B,21i-B, Power Mate i)
Series 90B1/A(01) and subsequent editions
(*) When the PDM is used, it must be supported by the CNC system
software. (With the system software series listed below, the PDM
can be used.)
CNC model Series and edition
16i-MB
B0HA-17 and subsequent editions
18i-MB
BDHA-17 and subsequent editions
18i-MB5
BDHE-07 and subsequent editions
21i-MB
DDHA-17 and subsequent editions
Power Mate i-D
88E1-01 and subsequent editions
Power Mate i-H
88F2-01 and subsequent editions
(3) Setting parameters
(a) Setting for the PDM
When the PDM is used for an axis, servo HRV3 control must be set
for the axis. Set the parameter shown below.
After setting parameters with servo HRV2 control specified, set servo
HRV3 control by parameter setting as follows (
HRV3 = 1). (For each
axis)
#7 #6 #5 #4 #3 #2 #1 #0
2013 (FS16i)
HRV3
HRV3(#0) 1: Uses servo HRV3 control.
0: Does not use servo HRV3 control.
(*) To use the PDM, set
HRV3 to 1. In actual control, operation
equivalent to HRV2 takes place. (It is also impossible to perform
switching between high-speed current control modes by G5.4.)
For the axis for which the PDM is used, set the following parameter in
addition to the above HRV3 setting.
2165 (FS16i)
Set 0.
If this setting is omitted, the invalid motor-amplifier combination state
may occur.
(b) Setting for 16-pole servo motors
For an axis for which one of the following servo motor is used, set the
following parameter for 16-pole servo motors:
Servo motor name Motor specification
αiS2000/2000HV
0091
αiS3000/2000HV
0092
#7 #6 #5 #4 #3 #2 #1 #0
2220 (FS16i)
P16
P16(#5) 1: Uses a 16-pole servo motor.
0: Does not use a 16-pole servo motor.