4.SERVO FUNCTION DETAILS B-65270EN/05
- 268 -
4.12.2 Cutting/Rapid Unexpected Disturbance Torque Detection
Switching Function
(1) Overview
An alarm threshold for unexpected disturbance torque detection is set
separately for cutting and rapid traverse.
(2) Series and editions of applicable servo software
(Series 30i,31i,32i)
Series 90D0/A(01) and subsequent editions
Series 90E0/A(01) and subsequent editions
(Series 15i-B,16i-B,18i-B,21i-B,0i-B,0i Mate-B,Power Mate i)
Series 9096/A(01) and subsequent editions
Series 90B0/A(01) and subsequent editions
Series 90B1/A(01) and subsequent editions
Series 90B6/A(01) and subsequent editions
(Series 0i-C,0i Mate-C,20i-B)
Series 90B5/A(01) and subsequent editions
(3) Setting parameters
A threshold can be set separately for cutting and rapid traverse by
setting the following bit when the unexpected disturbance torque
detection function is used:
#7 #6 #5 #4 #3 #2 #1 #0
1740 (FS15i)
ABG0
2200 (FS30i, 16i)
ABG0(#3) The cutting feed/rapid unexpected disturbance torque detection
switching function is:
1: Enabled.
0: Disabled.
#7 #6 #5 #4 #3 #2 #1 #0
2603 (FS15i)
ABT2
2215 (FS30i, 16i)
ABT2(#7) Cutting feed/rapid unexpected disturbance torque detection switching
function type-2 is:
1: Enabled.
0: Disabled.
NOTE
1 Set the two bits above. (Servo software was
revised in type-2 to be able to switch even if you
set No.1800#3=1, Feed-forward always enable.)
2 With Series 9096, switching is disabled when bit 3
of No. 1800 is set to 1 (to enable feed-forward in
rapid traverse). The alarm level for cutting is
enabled at all times.