4.SERVO FUNCTION DETAILS B-65270EN/05
- 164 -
HBPE (#4) The pitch error compensation is added to the error count of:
1: The semi-closed loop.
0: The closed loop. (Standard setting)
#7 #6 #5 #4 #3 #2 #1 #0
1746 (FS15i)
HBSF
2206 (FS30i, 16i)
HBSF (#4) A backlash compensation and pitch error compensation are:
1: Added to the closed loop side and semi-closed loop side at the
same time.
0: Added after selection according to the conventional parameter
(No. 1954 (Series 15i) or No. 2010 (Series 30i, 16i, and so on)).
When this parameter is set to 1, the settings of No. 1954 (Series
15i) and No. 2010 (Series 30i, 16i, and so on)are ignored.
(5) Zero-width setting for a machine with a large backlash or twist
Dual position feedback function (or hybrid function) is used for an
axis where a machine backlash of about 1/10 revolution in terms of
the motor shaft exists, the machine may stop with a position error
remaining, which is greater than the dual position feedback zero-width
parameter value. (In some cases, there may be ten or more pulses left.)
To solve this problem, make the following settings:
#7 #6 #5 #4 #3 #2 #1 #0
1742 (FS15i)
DUAL0W
2202 (FS30i, 16i)
DUAL0W (#4) The zero-width determination is performed with:
0: Setting = 0 only.
1: Setting. ← Set this value.
(6) Cautions on setting of the dual position feedback conversion coefficient
CAUTION
The dual position feedback conversion coefficient
is set as explained in Art. (4). With the conventional
calculation method, however, cancellation may
occur in the conversion coefficient of the servo
software depending on constants such as the
machine deceleration ratio. If cancellation in the
conversion coefficient occurs, feedback errors in
the semi-closed loop system are accumulated. In
some cases, this may result in motor oscillation.
To prevent this problem, calculate and set the dual
position feedback conversion coefficient by
following the procedure given below.