B-65270EN/05 5.DETAILS OF PARAMETERS
- 385 -
RCNCLR (#1) The speed data is:
0: Not cleared.
1: Cleared. (To use the RCN223 or RCN723, set it to 1.)
[Reference item] Subsection 2.1.4
[Related parameters] 2807 (15i), 2394 (16i etc.)
ASYN (#3) Synchronous axes automatic compensation function is:
0: Disabled.
1: Enabled.
[Reference item] Section 4.7
#7 #6 #5 #4 #3 #2 #1 #0
2696 (FS15i)
NOG54
2283 (FS30i, 16i)
NOG54(#0) High-speed HRV current control mode (servo R See the description of
HRV3 control in Section 4.2) is:
0: Used only when both G5.4Q1 and G01 are specified.
1: Used when G01 is specified. (G5.4Q1 is not monitored.)
NOTE
This function can be used when servo HRV3
control is used with the servo software for the
Series 30i/31i/32i (Series 90D0 and 90E0).
This function cannot be used when servo HRV4
control is used.
[Reference item] Section 4.2
#7 #6 #5 #4 #3 #2 #1 #0
2713 (FS15i)
CKLNOH HRVEN
2300 (FS30i, 16i)
HRVEN(#0) The extended HRV function is:
0: Not used.
1: Used.
NOTE
Set this function when using servo HRV4 control.
[Reference item] Section 4.2
CKLNOH (#7) Determination of an overheat via the PMC is:
0: Not performed.
1: Performed.
[Reference item] Subsection 4.14.2