B-65270EN/05 4.SERVO FUNCTION DETAILS
- 297 -
4.14.2 Detection of an Overheat Alarm by Servo Software When a
Linear Motor and a Synchronous Built-in Servo Motor are
Used
(1) Overview
When a linear motor and a synchronous built-in servo motor are used,
the motor overheat signal cannot be posted to the CNC via a detector.
Therefore, to detect a motor overheat, alarm processing for the
thermostat signal had to be performed by a PMC ladder. (For details,
refer to Section 2.5, "THERMOSTAT CONNECTION", in Part III,
"HANDLING, DESIGN, AND ASSEMBLY", in "FANUC LINEAR
MOTOR Lis series DESCRIPTIONS (B-65382EN).)
This function uses servo software to monitor the thermostat signal
applied to DI and issues a servo alarm (motor overheat) when an
overheat occurs. Use of this function eliminates the need to perform
alarm processing by using the PMC ladder.
In addition, when an overheat alarm is issued, quick stop processing
(quick stop function with velocity command 0) can be used. (For
details, see Subsection 4.11.5, "Quick Stop Function at OVL (Motor
Overheat) and OVC (Over Current) Alarm".)
Conventional overheat processing
Linear
motor
PMC
controller
CNC
controller
CNC
ladder program created by
the machine tool builder
detects an alarm and transfers
it to the CNC.
Thermo-
stat
The CNC performs
emergency stop processing.
Servo
controller
Emergency
stop
Overheat processing when this function is used
Linear
motor
CNC
Thermo-
stat
The thermostat
status is posted to
the servo CPU and
is detected as a
servo alarm.
Servo
controller
Thermostat
status
larm
PMC
controller
CNC
controller