B-65270EN/05 5.DETAILS OF PARAMETERS
- 373 -
ANALOG(#4) Analog servo interface function is:
0: Not used
1: Used
[Reference item] Appendix A
BLCU(#6) The function that validates the backlash acceleration function only at
cutting is:
0: Invalidated.
1: Validated.
[Reference item] Subsections 4.6.6 and 4.6.7
BLST (#7) The backlash acceleration stop function is:
0: Not used.
1: Used .
[Reference item] Subsection 4.6.6
[Related parameters] 1975 (15i), 2082 (16i etc.)
#7 #6 #5 #4 #3 #2 #1 #0
1954 (FS15i)
POLE HBBL HBPE BLTE LINEAR
2010 (FS30i, 16i)
LINEAR (#2) 1: Controls a linear motor.This bit is set automatically when the
parameters of the linear motor are initialized. Check that this bit
is set before the linear motor is driven.
[Reference item] Subsec. 4.14.1.
BLTE (#3) The function to multiply the backlash acceleration amount by 10 is:
0: Invalidated.
1: Validated.
[Reference item] Subsections 4.6.6 and 4.6.7
HBPE (#4) When the dual position feedback function is used, a pitch error
compensation is added to the error counter of:
0: Full-closed loop. ← Standard setting
1: Semi-closed loop.
[Reference item] Subsection 4.5.7
HBBL (#5) When the dual position feedback function is used, a backlash
compensation amount is added to the error counter of:
0: Semi-closed loop. ← Standard setting
1: Full-closed loop.
[Reference item] Subsection 4.5.7
POLE (#7) The punch/laser switching function is:
0: Not used.
1: Used.