B-65270EN/05 4.SERVO FUNCTION DETAILS
- 187 -
With following series and editions of servo software, the bit shown
below can also be used to enable the backlash acceleration function
only during cutting.
- Series 90B0/C(03) and subsequent editions
- Series 90B6/A(01) and subsequent editions
- Series 90B5/A(01) and subsequent editions
- Series 90D0/A(01) and subsequent editions
- Series 90E0/A(01) and subsequent editions
Use of this bit enables and disables the backlash acceleration function
even when bit 3 of parameter No. 1800 is set to 1. Backlash
acceleration is enabled even at the hole bottom during rigid tapping.
#7 #6 #5 #4 #3 #2 #1 #0
2611 (FS15i)
BLCUT2
2223 (FS30i, 16i)
BLCUT2 (#7) 1: To enable the backlash acceleration function during cutting feed
only
[Reference] Adjustment the backlash acceleration
Run a program for an arc, and make an adjustment while
checking the arc figure on SERVO GUIDE.