B-65270EN/05 2. SETTING αiS/αiF/βiS SERIES SERVO PARAMETERS
- 25 -
2.1.4 Setting Servo Parameters when a Separate Detector for the
Serial Interface is used
(1) Overview
When a separate detector of the serial output type is used, there is a
possibility that the detection unit becomes finer than the detection unit
currently used. Accordingly, a few modifications are made to the
setting method and values of servo parameters.
When using a separate detector of the serial output type, follow the
method explained below to set parameters.
(2) Series and editions of applicable servo software
(Series 30i,31i,32i)
Series 90D0/A(01) and subsequent editions
Series 90E0/A(01) and subsequent editions
(Series 15
i-B,16i-B,18i-B,21i-B,0i-B,0i Mate-B,Power Mate i)
Series 90B0/A(01) and subsequent editions
Series 90B1/A(01) and subsequent editions
Series 90B6/A(01) and subsequent editions
(Series 0
i-C,0i Mate-C,20i-B)
Series 90B5/A(01) and subsequent editions
(3) Classification of serial detectors and usable detector examples
Usable separate detectors for the serial interface are classified into
four major types as shown below. Note that parameter settings vary
with these types.
(a) Serial output type linear encoder
Minimum resolution Model Backup
MITSUTOYO Co., Ltd.
0.05µm
AT353, AT553 Not required
HEIDENHAIN
0.05µm/0.1µm
0.05µm/0.1µm
LC191F
LC491F
Not required
Not required
(b) Analog output type linear encoder plus high-resolution serial converter
manufactured by FANUC
Signal pitch Model Backup
MITUTOYO Co., Ltd.
20µm
AT402 Required
HEIDENHAIN
20µm
LS486, LS186 Required
Sony Precision Technology Inc.
20µm
SH12 Required
(c) Serial output type rotary encoder
Minimum resolution
(Note 1)
Model Backup
FANUC 2
20
pulse/rev αA1000S Required